Pfeiffer P3 OilClear, monograde oil that has the correct viscosity for Pfeiffer Rotary pumps, excellent sealing and lubrication properties, low vapor pressure and reduced back streaming.Used also for Prod. No. 7010 and 7010-220 Rotary Pumps. MSDS Typical properties of Pfeiffer P3 Oil
|
||||||||||||||||||||
![]() |
Ultragrade 19 OilMineral oil derivative ideally suited for mechanical rotary vacuum pumps. Light end fractions are removed through molecular distillation resulting in lower vapor pressures and reduced backstreaming compared to undistilled refinery products. Offers reduced maintenance costs, longer fluid life and cooler running. Suitable for single and dual rotary vane pumps from VRL, BOC-Edwards, Alcatel, Adixen, Varian, Leybold, Sargent-Welch, ULVAC and other brands. MSDSTypical properties of Ultra Grade 19 Oil
|
||||||||||||||||||||
![]() |
Krytox® 1525 Vacuum Pumping FluidKrytox® Perfluorinated Polyether (PFPE) inert vacuum pump fluid for corrosive and oxygen applications. Chemically inert pumping fluid with excellent lubrication properties. Used in chemical resistant pumps as used in plasma cleaning systems.Typical properties of Krytox® 1525 Vacuum Pumping Fluid
|
||||||||||||||||||||
|
Santovac® 5 Diffusion Pump OilSantovac® 5 Polyphenyl Ether Vacuum Pump Fluidexcellent for TEM, SEM
Operates efficiently, economically and safely in diffusion pumps in properly designed systems to produce
ultra-high vacuums in the 10-10 torr range. A wide liquid range, low vapor pressure and balance
of properties make it an ideal working fluid in diffusion pumps. |
||||||||||||||||||||
|
Low backstreaming. Santovac® 5 pump fluid can be used for electronic component manufacture,
laboratory, analytical, instrument and research applications.
|
|||||||||||||||||||||
|
Lion S Diffusion Pump oilLion S diffusion pump oil is a high quality alkyl naphthalene based diffusion pump oil, especially developed for applications such as electron microscopes, mass spectrometers and small vacuum systems. Recommended for TEMs and SEMs made by Hitachi, JEOL and ISI/ABT/Topcon equipped with a diffusion pump. No need for lower grade substitutes, this is the original LION S diffusion pump oil, manufactured by the Lion Corporation, Japan. It has been and is still used in diffusion pumps used in instruments manufactured in Japan. Lion S diffusion oil has a high resistance against oxidation and works well with small and medium size diffusion pumps.Typical properties of Lion S Diffusion Pump Oil MSDS (PDF 119KB) Technical Notes (PDF 137KB) |
||||||||||||||||||||
|
|
|||||||||||||||||||||
|
|
Exhaust Filter for 7010 and GD6 Rotary Pumps(mist eliminators) Filter for removing oil mist from vacuum pump exhaust in Prod. No. 7010, 7010-220, 91010 and 91010-230 Rotary Pumps or any other rotary vane pump with NW/KF 16 output flange, creates a cleaner work environment for operators and surrounding equipment. Connection: 1/4" NPT thread. |
||||||||||||||||||||
|
|
|||||||||||||||||||||
Exhaust Filters for Premium Vacuum Rotary Vane PumpsFilters for removing oil mist from exhaust in the VRL and Edwards rotary vane pumps. Permits discharge into clean work areas. Return collected oil to sump or discard. Rugged construction, simple installation. For non-hazardous, non-corrosive applications. |
|||||||||||||||||||||
|
|
|||||||||||||||||||||
|
Compact Oil Mist EliminatorCompact Oil Mist Eliminator with KF25 connection and 1/8" drain plug. Max flow rate 10 CFM (5 ltr/sec or 16m3/hr (suitable for #92081, 92082, 92035 and 92035-220). Baked enamel steel housing, ø89 x 127mm H (ø3.5" x 5" H). Use replacement filter #92066-10.
|
||||||||||||||||||||
|
Foreline TrapsHighly recommended to prevent oil backstreaming from rotary vane pumps. Keeps your vacuum system clean in applications where pumps are running constantly such as mass specrometer, electron microscope, and vacuum drying systems. Protect vacuum gauges when mounted in front of the gauges. Includes a 150ml Activated Alumina charge (renew the charge every 3 months with Prod. No. 92090-50). These compact, reliable and efficient foreline traps offer maximum mounting flexibility and have the following features: |
|||||||||||||||||||||||||
|
||||||||||||||||||||||||||
|
|
||||||||||||||||||||||||||
![]() |
PELCO® Activated Alumina Sorbent for Forline TrapsThe activated alumina sorbent is used in foreline traps to prevent backstreaming from rotary pumps or to
shield vacuum gauges from contamination. PELCO® activated alumina sorbent can be used in foreline traps
from VRL, BOC-Edwards, Alcatel/Adixen, Varian, Leybold, Sargent-Welch, Ulvac and other brands. The small pores
(2-50nm) and the non uniform pore distribution in the PELCO® activated alumina provide the large surface
area of 350 m2/gram. With this large internal surface area, the activated alumina sorbent attracts and holds
gas molecules to which it is exposed. PELCO® activated alumina is activated at 350°C (662°F) to
less than 1% water and it is capable of holding 43% water (by weight) or in the foreline trap application,
oil. The relatively uniform 1/4" diameter size makes it ideally suited for charging perforated mesh
canisters as used in foreline fraps. |
|||||||||||||||||||||||||
|
|
||||||||||||||||||||||||||